Product Overview
The Vertical Single-Stage Fire Pump is a high-efficiency centrifugal pump designed to provide reliable water supply for fire protection systems in commercial, industrial, and municipal applications. Its compact vertical structure minimizes installation space while ensuring stable operation, low vibration, and easy maintenance.
This pump is widely used in automatic sprinkler systems, hydrant systems, pressure boosting stations, high-rise buildings, factories, warehouses, shopping centers, hospitals, airports, and other facilities requiring dependable fire water supply. It can also be applied to industrial water transfer, municipal water distribution, district heating, HVAC circulation, and long-distance water transportation.
Manufactured with high-quality hydraulic components and precision machining, the pump delivers excellent efficiency, stable performance, and a long service life. Various flow rates, heads, materials, motor voltages, and frequency options are available to meet different project requirements. OEM and customized solutions are also supported for international engineering projects.

| Parameter Description | |
| Item | Range |
|---|---|
| Flow | 5–150 L/s |
| Head | 32–150 m |
| Power | 4–160 kW |
| Speed | 1450/2900 rpm |
* If special requirements are needed, please feel free to contact us.
Core Advantages
Compact Structure
Vertical in-line design
Space-saving installation
Easy piping connection
Convenient maintenance
Reliable Performance
Stable water pressure
Wide performance range
Low vibration
High operating efficiency
Quality Assurance
Factory performance tested
Reliable mechanical seal
Durable hydraulic components
Long service life
Application
Fire Protection Systems
Fire hydrant systems
Automatic sprinkler systems
Water mist and deluge fire suppression systems
Fire water supply for commercial buildings, hospitals, schools, factories, warehouses, and high-rise buildings
General Water Supply
Pressure boosting for high-rise buildings
Booster pump stations and long-distance water transmission
Industrial circulating water systems
HVAC and boiler water circulation systems
Municipal water supply and drainage systems
Water transfer and pressure boosting for water treatment plants

How to Select the Right Vertical Fire Pump
Determine Required Flow & Head
Select the pump according to the required flow rate (L/s) and head (m) specified in your fire protection system design.
Choose the Appropriate Drive Type
Select an electric motor, diesel engine, or complete fire pump set based on your project requirements and local fire codes.
Confirm Standards & Installation
Verify the required standards (NFPA 20, CCCF, ISO, etc.), power supply, installation space, and pipe connections before selecting the final model.
|
Serial Number |
Model |
Rated Flow Rate L/S |
Rated Head(m) |
Speed |
Motor Power |
Serial Number |
Model |
Rated Flow Rate L/S |
Rated Head(m) |
Speed |
Motor Power |
|
1 |
XBD3.2/5G-TSL |
5
|
32 |
2900 |
4 |
27 |
XBD3.2/20G-TSL |
20 |
32 |
2900 |
15 |
|
2 |
XBD4.0/5G-TSL |
40 |
2900 |
7.5 |
28 |
XBD3.8/20G-TSL |
38 |
2900 |
18.5 |
||
|
3 |
XBD5.0/5G-TSL |
50 |
2900 |
7.5 |
29 |
XBD4.5/20G-TSL |
45 |
2900 |
18.5 |
||
|
4 |
XBD6.0/5G-TSL |
60 |
2900 |
11 |
30 |
XBD5.2/20G-TSL |
52 |
2900 |
22 |
||
|
5 |
XBD7.0/5G-TSL |
70 |
2900 |
11 |
31 |
XBD6.0/20G-TSL |
60 |
2900 |
22 |
||
|
6 |
XBD8.0/5G-TSL |
80 |
2900 |
15 |
32 |
XBD7.0/20G-TSL |
70 |
2900 |
30 |
||
|
7 |
XBD3.2/10G-TSL |
10
|
32 |
2900 |
7.5 |
33 |
XBD8.0/20G-TSL |
80 |
2900 |
37 |
|
|
8 |
XBD4.0/10G-TSL |
40 |
2900 |
11 |
34 |
XBD9.0/20G-TSL |
90 |
2900 |
45 |
||
|
9 |
XBD5.0/10G-TSL |
50 |
2900 |
15 |
35 |
XBD10.0/20G-TSL |
100 |
2900 |
45 |
||
|
10 |
XBD6.0/10G-TSL |
60 |
2900 |
15 |
36 |
XBD11.0/20G-TSL |
110 |
2900 |
55 |
||
|
11 |
XBD7.0/10G-TSL |
70 |
2900 |
18.5 |
37 |
XBD12.5/20G-TSL |
125 |
2900 |
75 |
||
|
12 |
XBD8.0/10G-TSL |
80 |
2900 |
22 |
38 |
XBD13.0/20G-TSL |
130 |
2900 |
75 |
||
|
13 |
XBD9.0/10G-TSL |
90 |
2900 |
30 |
39 |
XBD14.0/20G-TSL |
140 |
2900 |
75 |
||
|
14 |
XBD10.0/10G-TSL |
100 |
2900 |
30 |
40 |
XBD15.0/20G-TSL |
150 |
2900 |
90 |
||
|
15 |
XBD11.0/10G-TSL |
110 |
2900 |
37 |
41 |
XBD3.2/25G-TSL |
25 |
32 |
2900 |
15 |
|
|
16 |
XBD3.2/15G-TSL |
15
|
32 |
2900 |
7.5 |
42 |
XBD3.8/25G-TSL |
38 |
2900 |
18.5 |
|
|
17 |
XBD4.0/15G-TSL |
40 |
2900 |
11 |
43 |
XBD4.5/25G-TSL |
45 |
2900 |
18.5 |
||
|
18 |
XBD5.0/15G-TSL |
50 |
2900 |
15 |
44 |
XBD5.0/25G-TSL |
50 |
2900 |
22 |
||
|
19 |
XBD5.5/15G-TSL |
55 |
2900 |
15 |
45 |
XBD6.0/25G-TSL |
60 |
2900 |
22 |
||
|
20 |
XBD6.0/15G-TSL |
60 |
2900 |
15 |
46 |
XBD7.0/25G-TSL |
70 |
2900 |
30 |
||
|
21 |
XBD7.0/15G-TSL |
70 |
2900 |
18.5 |
47 |
XBD8.0/25G-TSL |
80 |
2900 |
37 |
||
|
22 |
XBD8.0/15G-TSL |
80 |
2900 |
22 |
48 |
XBD9.0/25G-TSL |
90 |
2900 |
45 |
||
|
23 |
XBD9.0/15G-TSL |
90 |
2900 |
30 |
49 |
XBD10.0/25G-TSL |
100 |
2900 |
45 |
||
|
24 |
XBD10.0/15G-TSL |
100 |
2900 |
30 |
50 |
XBD11.0/25G-TSL |
110 |
2900 |
55 |
||
|
25 |
XBD11.0/15G-TSL |
110 |
2900 |
37 |
51 |
XBD12.5/25G-TSL |
125 |
2900 |
75 |
||
|
26 |
XBD12.0/15G-TSL |
120 |
2900 |
45 |
52 |
XBD13.0/25G-TSL |
130 |
2900 |
75 |
||
|
53 |
XBD14.0/25G-TSL |
25 |
140 |
2900 |
75 |
82 |
XBD15.0/35G-TSL |
35 |
150 |
2900 |
110 |
|
54 |
XBD15.0/25G-TSL |
150 |
2900 |
90 |
83 |
XBD3.2/40G-TSL |
40 |
32 |
2900 |
22 |
|
|
55 |
XBD3.2/30G-TSL |
30 |
32 |
2900 |
15 |
84 |
XBD3.8/40G-TSL |
38 |
2900 |
30 |
|
|
56 |
XBD3.8/30G-TSL |
38 |
2900 |
18.5 |
85 |
XBD4.5/40G-TSL |
45 |
2900 |
30 |
||
|
57 |
XBD4.5/30G-TSL |
45 |
2900 |
18.5 |
86 |
XBD5.0/40G-TSL |
50 |
2900 |
37 |
||
|
58 |
XBD5.0/30G-TSL |
50 |
2900 |
22 |
87 |
XBD6.0/40G-TSL |
60 |
2900 |
37 |
||
|
59 |
XBD6.0/30G-TSL |
60 |
2900 |
30 |
88 |
XBD7.0/40G-TSL |
70 |
2900 |
45 |
||
|
60 |
XBD7.0/30G-TSL |
70 |
2900 |
30 |
89 |
XBD8.0/40G-TSL |
80 |
2900 |
55 |
||
|
61 |
XBD8.0/30G-TSL |
80 |
2900 |
37 |
90 |
XBD9.0/40G-TSL |
90 |
2900 |
55 |
||
|
62 |
XBD9.0/30G-TSL |
90 |
2900 |
45 |
91 |
XBD10.0/40G-TSL |
100 |
2900 |
75 |
||
|
63 |
XBD10.0/30G-TSL |
100 |
2900 |
45 |
92 |
XBD11.0/40G-TSL |
110 |
2900 |
75 |
||
|
64 |
XBD11.0/30G-TSL |
110 |
2900 |
55 |
93 |
XBD12.5/40G-TSL |
125 |
2900 |
90 |
||
|
65 |
XBD12.5/30G-TSL |
125 |
2900 |
75 |
94 |
XBD13.0/40G-TSL |
130 |
2900 |
90 |
||
|
66 |
XBD13.0/30G-TSL |
130 |
2900 |
75 |
95 |
XBD14.0/40G-TSL |
140 |
2900 |
90 |
||
|
67 |
XBD14.0/30G-TSL |
140 |
2900 |
90 |
96 |
XBD15.0/40G-TSL |
150 |
2900 |
110 |
||
|
68 |
XBD15.0/30G-TSL |
150 |
2900 |
90 |
97 |
XBD3.2/50G-TSL |
50 |
32 |
2900 |
22 |
|
|
69 |
XBD3.2/35G-TSL |
35 |
32 |
2900 |
22 |
98 |
XBD3.8/50G-TSL |
38 |
2900 |
30 |
|
|
70 |
XBD3.8/35G-TSL |
38 |
2900 |
30 |
99 |
XBD4.5/50G-TSL |
45 |
2900 |
30 |
||
|
71 |
XBD4.5/35G-TSL |
45 |
2900 |
30 |
100 |
XBD5.0/50G-TSL |
50 |
2900 |
37 |
||
|
72 |
XBD5.0/35G-TSL |
50 |
2900 |
37 |
101 |
XBD6.0/50G-TSL |
60 |
2900 |
45 |
||
|
73 |
XBD6.0/35G-TSL |
60 |
2900 |
37 |
102 |
XBD7.0/50G-TSL |
70 |
2900 |
55 |
||
|
74 |
XBD7.0/35G-TSL |
70 |
2900 |
45 |
103 |
XBD8.0/50G-TSL |
80 |
2900 |
75 |
||
|
75 |
XBD8.0/35G-TSL |
80 |
2900 |
55 |
104 |
XBD9.0/50G-TSL |
90 |
2900 |
75 |
||
|
76 |
XBD9.0/35G-TSL |
90 |
2900 |
55 |
105 |
XBD10.0/50G-TSL |
100 |
2900 |
90 |
||
|
77 |
XBD10.0/35G-TSL |
100 |
2900 |
75 |
106 |
XBD11.0/50G-TSL |
110 |
2900 |
90 |
||
|
78 |
XBD11.0/35G-TSL |
110 |
2900 |
75 |
107 |
XBD12.5/50G-TSL |
125 |
2900 |
110 |
||
|
79 |
XBD12.5/35G-TSL |
125 |
2900 |
90 |
108 |
XBD13.0/50G-TSL |
130 |
2900 |
110 |
||
|
80 |
XBD13.0/35G-TSL |
130 |
2900 |
90 |
109 |
XBD14.0/50G-TSL |
140 |
2900 |
110 |
||
|
81 |
XBD14.0/35G-TSL |
140 |
2900 |
90 |
110 |
XBD15.0/50G-TSL |
150 |
2900 |
110 |
||
|
111 |
XBD4.0/60G-TSL |
60 |
40 |
2900 |
30 |
140 |
XBD5.0/100G-TSL |
100 |
50 |
2900 |
90 |
|
112 |
XBD5.0/60G-TSL |
50 |
2900 |
37 |
141 |
XBD6.0/100G-TSL |
60 |
2900 |
110 |
||
|
113 |
XBD6.0/60G-TSL |
60 |
2900 |
45 |
142 |
XBD7.0/100G-TSL |
70 |
2900 |
160 |
||
|
114 |
XBD7.0/60G-TSL |
70 |
2900 |
55 |
143 |
XBD8.0/100G-TSL |
80 |
2900 |
160 |
||
|
115 |
XBD8.0/60G-TSL |
80 |
2900 |
75 |
144 |
XBD9.0/100G-TSL |
90 |
2900 |
160 |
||
|
116 |
XBD9.0/60G-TSL |
90 |
2900 |
75 |
145 |
XBD10.0/100G-TSL |
100 |
2900 |
160 |
||
|
117 |
XBD10.0/60G-TSL |
100 |
2900 |
90 |
146 |
XBD11.0/100G-TSL |
110 |
2900 |
160 |
||
|
118 |
XBD11.0/60G-TSL |
110 |
2900 |
90 |
147 |
XBD6.0/110G-TSL |
110 |
60 |
2900 |
110 |
|
|
119 |
XBD12.5/60G-TSL |
125 |
2900 |
110 |
148 |
XBD7.0/110G-TSL |
70 |
2900 |
132 |
||
|
120 |
XBD13.0/60G-TSL |
130 |
2900 |
110 |
149 |
XBD7.4/110G-TSL |
74 |
2900 |
132 |
||
|
121 |
XBD14.0/60G-TSL |
140 |
2900 |
110 |
|
|
|
|
|
|
|
|
122 |
XBD15.0/60G-TSL |
150 |
2900 |
110 |
|
|
|
|
|
|
|
|
123 |
XBD5.0/70G-TSL |
70 |
50 |
2900 |
37 |
|
|
|
|
|
|
|
124 |
XBD6.0/70G-TSL |
60 |
2900 |
55 |
|
|
|
|
|
|
|
|
125 |
XBD7.0/70G-TSL |
70 |
2900 |
75 |
|
|
|
|
|
|
|
|
126 |
XBD8.0/70G-TSL |
80 |
2900 |
75 |
|
|
|
|
|
|
|
|
127 |
XBD9.0/70G-TSL |
90 |
2900 |
90 |
|
|
|
|
|
|
|
|
128 |
XBD10.0/70G-TSL |
100 |
2900 |
90 |
|
|
|
|
|
|
|
|
129 |
XBD11.0/70G-TSL |
110 |
2900 |
110 |
|
|
|
|
|
|
|
|
130 |
XBD12.5/70G-TSL |
125 |
2900 |
110 |
|
|
|
|
|
|
|
|
131 |
XBD13.0/70G-TSL |
130 |
2900 |
110 |
|
|
|
|
|
|
|
|
132 |
XBD15.0/70G-TSL |
140 |
2900 |
132 |
|
|
|
|
|
|
|
|
133 |
XBD6.0/80G-TSL |
80 |
60 |
2900 |
90 |
|
|
|
|
|
|
|
134 |
XBD7.0/80G-TSL |
70 |
2900 |
90 |
|
|
|
|
|
|
|
|
135 |
XBD8.0/80G-TSL |
80 |
2900 |
110 |
|
|
|
|
|
|
|
|
136 |
XBD9.0/80G-TSL |
90 |
2900 |
110 |
|
|
|
|
|
|
|
|
137 |
XBD10.0/80G-TSL |
100 |
2900 |
132 |
|
|
|
|
|
|
|
|
138 |
XBD11.0/80G-TSL |
110 |
2900 |
132 |
|
|
|
|
|
|
|
|
139 |
XBD12.5/80G-TSL |
125 |
2900 |
160 |
|
|
|
|
|
|
Vertical Single-Stage Fire Pump Operation and Maintenance Notes
- Before installation, inspect the pump body and motor for damage, check that the inlet and outlet pipelines are unobstructed, and verify that the seals are intact.
- Fill the pump with water completely before initial startup to prevent mechanical seal damage caused by dry running.
- Inspect the motor insulation and impeller cleanliness every 3 months, and conduct a full maintenance check annually.
- When the pump is idle for an extended period, drain all water inside, perform anti-rust treatment, and start it up for 5–10 minutes at regular intervals




Hot Tags: vertical single-stage fire pump, China vertical single-stage fire pump manufacturers, suppliers, factory, home fire fighting water pump system, priming fire pump, residential fire pump, fire fighting pump, fire fighting water pump, Vertical Pipeline Fire Pump